top of page
charged plate.jpg
CPM-766 Charged Plate Monitor
  • Measures Decay and Balance (Offset Voltage) in accordance with ANSI/ESD STM3.1 and IEC 61340-4-7

  • Uses rechargeable Li-ion batteries

  • Up to 250 hours of battery life

  • Automated test sequences of tests

  • Selectable stop voltages for decay tests

  • Programmable delayed start option

  • Large color touchscreen LCD display

  • Built-in temperature and humidity sensor

  • Internal memory up to 200 data sets

  • Fast response time

  • Analog outout

  • NIST calibration included

www.prostatcorp.com

prs 801b.jpg

PRS-801B Resistance System

  • Accurate Wide Range Resistance Measurements: 0.01 Ω to 2.00x1014 Ω

  • Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω

  • Variable Voltage 0.1 mv to 9.99 V for low resistance measurements

  • Constant Test voltages 10V and 100V meeting ANSI/ESD S20.20

  • Auto Resistance Range Control

  • Auto Test Voltage Control

  • Uses a Rechargeable Li-ion Battery Pack

  • Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)

  • 999 Data Set Memory

  • Download to Excel® in Batches or Individual Measurements with Prostat Connect 2.0

  • Uses Micro USB Cable for Charging and Downloading Data

  • Charges in 2 Hours

  • 2-year Limited Warranty on Main Instrument


www.prostatcorp.com

prs 812b.jpg

PRS-812B Resistance Meter

  • Wide Range Resistance: 0.10 Ω to 1.00x1012 Ω

  • Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω

  • Constant Test voltages 10V and 100V for specification measurements to meet international and domestic ESD measurement standards

  • Auto Resistance Range Control

  • Auto Test Voltage Control

  • Uses a Rechargeable Li-ion Battery Pack

  • Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)

  • 120 Data Set Internal Memory

  • Uses Standard USB Cable for Charging

  • Charges in 2 Hours

  • 2-year Limited Warranty on Main Instrument


www.prostatcorp.com

wide range ohmmeter.jpg

PAS-853B Wide Range Ohmmeter

  • Wide Resistance Measurement Range from 0.01 ohm to 9.99x1012 ohms

  • Nominal Full Range Tolerance Averages <±5%

  • Fully Automatic Resistance Range, Test Voltage and Electrification Period Control

  • Automatic or Continuous Electrification Control

  • Rugged High Performance 80 inches (200cm) Test Leads Included

  • Powered by one long lasting 9V Alkaline Battery

  • Large, Easy to Read LCD Display

  • Meets requirements of ESD Association Standards for material and audit resistance measurement requirements

  • Certificate of Calibration Traceable to NIST included


www.prostatcorp.com

handheld electrostatic.jpg

PFM-711B Electrostatic Field Meter
 

  • Lightweight, portable, hand-held Field Meter

  • Measure in 1 volt/in increments 0 to ±1,999 Volts

  • Measure in 10 V/in increments 0 to ±20,000 Volts

  • Accuracy of <±5%

  • LED ranging lights help position the meter at the right distance

  • Zero button allows the display to be adjusted to zero (0)

  • Hold feature freezes the measurement on the display

  • Use with Prostat CPM-720B Charge Plate Monitor and PCS-730B Electrostatic Charger

  • Use with Prostat PGA-710B AutoAnalysis System or X-Y Plotter

  • Analyze Footwear/Flooring Combinations

  • Verify Ionizer Balance and Decay Time Performance

  • 2-year Limited Warranty (1 year on the sensor)


www.prostatcorp.com

prf 922b.jpg

Surface Resistance per ANSI/ESD STM11.13

  • Measures volume resistance per ANSI/ESD STM11.13

  • Meets the requirements of IEC 61340-4-10

  • Measures Point-to-Point Surface Resistance from 0.9Ω to 1.0x1012Ω

  • Spacing Allows for Measurement Area of 0.325 inches (8.26mm)

  • Black Anodized Insulated Metal Probe

  • Gold Plated Spring Loaded Contact Pins

  • Removable Conductive Rubber Boots Included

  • Certificate of Calibration Traceable to NIST included


www.prostatcorp.com

concentric ring.jpg

PRF-911 Concentric Ring
 

  • Measures surface resistance per ANSI/ESD STM11.11

  • Measures volume resistance per ANSI/ESD STM11.12

  • Meets the requirements of IEC 61340-2-3

  • Approximates surface & volume resistivity per ASTM D-257

  • Incorporates a spring loaded, self-aligning center electrode feature to reduce calibration frequency

  • Includes an insulated and metal dual test bed

  • Designed to work with a wide range resistance meter and one 5 lb. electrode

  • Certificate of calibration traceable to NIST included



www.prostatcorp.com